• High stability internal reference
• Extended temperature range:
T1 (-40oC, +55oC)
T2 (-40oC, +60oC)
• Redundancy systems
(1:1, 2:1, N:1)
• SSPA version
Leading SatCom Distributor in the MEA Region


The Dual GaN Ka BUC from TTI is a GaN-Based BUC/SSPA that converts an input frequency from 1-2 GHz to an output frequency from 29-31 GHz. It delivers an output power of up to 40 W (46 dBm) with a gain of over 70 dB. This BUC has a built-in linearizer, output isolator & switchable…
• High stability internal reference
• Extended temperature range:
T1 (-40oC, +55oC)
T2 (-40oC, +60oC)
• Redundancy systems
(1:1, 2:1, N:1)
• SSPA version

| ELECTRICAL | |
| Input frequency range | 1-2 GHz |
| Output frequency range | 29-30 GHz / 30-31 GHz (electronically switchable) |
| Output Power (PSAT(typical)) | 46 dBm (40 W) from 29 to 30 GHz, 45 dBm (32 W) from 30 to 31 GHz |
| Linear Output Power (PLINEAR) | 43 dBm (20 W) from 29 to 30 GHz, 42 dBm (16 W) from 30 to 31 GHz |
| Gain | >70 dB |
| Gain flatness | 4 dB p-p max over full band; 1dB p-p max over any 40 MHz |
| Gain variation over temperature | ±1.5 dB over full operating range |
| Attenuation Adjustment Range | 20 dB in 0.1 dB step |
| Input impedance and VSWR | 50 Ω, ≤1.5:1 |
| Output VSWR | ≤1.3:1 |
| Phase noise | -63 dBc/Hz at 100 Hz, -73 dBc/Hz at 1 kHz, -83 dBc/Hz at 10 kHz, -93 dBc/Hz at 100 kHz |
| External reference frequency and phase noise |
10 MHz, 0 dBm ±5 dB (TX IF port multiplexed) -135 dBc/Hz at 100 Hz, -155 dBc/Hz at 1 kHz, -160 dBc/Hz at 10 kHz |
| Spectral regrowth | -30 dBc @ PLINEAR*
* For a single carrier with modulation DVB-S, 4MBaud, Roll-off: 0.25, ModCod |
| Spurious | -60 dBc max @ PLINEAR |
| POWER SUPPLY | |
| Input voltage | 90-264 VAC, 50-60 Hz |
| Power consumption @ PSAT | 350 W @ PSAT |
The Dual GaN Ka BUC from TTI is a GaN-Based BUC/SSPA that converts an input frequency from 1-2 GHz to an output frequency from 29-31 GHz. It delivers an output power of up to 40 W (46 dBm) with a gain of over 70 dB. This BUC has a built-in linearizer, output isolator & switchable local oscillator and provides the capability to adapt BUC configuration to the required output power, optimizing the consumption while keeping the same electrical specifications. It has a phase noise of -93 dBc/Hz @ 100 kHz offset and spurious levels off better than -60 dBc.
The BUC can be controlled via RS-485, Ethernet, and USB interfaces. It is available in a weatherproof module that measures 340 x 210 x 170 mm with an N-type (female) input connector and WR28 output interface. It requires an AC supply of 90-264 V and consumes 350 W of power.